470 opportunities

Page 10 of 10
Bid Number Bid Type Name Description Specifications Sight Briefing Date Closing Date
RFQ/OBP086/2025/26 Request for Quote To procure Tri-Sodium Citrate To procure Tri-Sodium Citrate To procure Tri-Sodium Citrate No 2025/07/20 15:00:00
RFQ/OBP069/2025/26 Request for Quote To procure VITAMIN C POWDER 25KG VITAMIN C POWDER 25KG VITAMIN C POWDER 25KG No 2025/06/23 15:00:00
RFQ/OBP374/2024/25 Request for Quote Tongue Cartons and leaflets See Specifications See Specifications No 2024/10/17 15:00:00
RFQ/OBP533/2024/25 Request for Quote Towelling and protective consumables Procurement Description:To procure Towelling and protective consumables to fill current stock levels while the panel RQF is being actioned. Note that these items are kept in stores. Bulk buying is cost effective, and it ensures that stock is available when needed. Procurement Description:To procure Towelling and protective consumables to fill current stock levels while the panel RQF is being actioned. Note that these items are kept in stores. Bulk buying is cost effective, and it ensures that stock is available when needed. No 2025/03/05 15:00:00
RFQ/OBP037/2025/26 Request for Quote TURNKEY PROCESS OF HEADHUNTING AND PLACEMENT OF THE CHIEF EXECUTIVE OFFICER Refer to ToR attached. Refer to ToR attached. No 2025/05/25 15:00:00
RFP/OBP05/24/IT01 Request for Proposal UPGRADE MICROSOFT DYNAMICS NAVISION 2009 TO MICROSOFT DYNAMICS 365 BUSINESS CENTRAL ERP TURNKEY PROJECT AS PER RFP AS PER RFP No 2024/11/04 13:00:00
RFQ/OBP032/2025/26 Request for Quote URGENT - Supply & install electrical Armoured cable with issue of COC on completion We urgently need assistance with procuring certain critical spares needed for the freeze drier project. 1. We urgently need to cut the floor for the power supply cable. We will need to hire a jack hammer as ours is missing from the stores (Security Manager was informed last week). 2. We need to buy a new cable. The current one has been in place since 1982, and the insulation may have deteriorated. It should have been tested but sadly that has not been done. Phophi had been informed last year around August that it had been tested but alas that was not the case – we do not have the equipment to test it ourselves (we do not even have a mega on site). For that reason, we cannot use it as that will be in breach of the electrical installation regulations. 3. Again, not to fall foul of the electrical installation regulations we need to install an electrical isolator. That has not been procured. Please use your good offices to facilitate the procurement of these spares and hiring services. We urgently need assistance with procuring certain critical spares needed for the freeze drier project. 1. We urgently need to cut the floor for the power supply cable. We will need to hire a jack hammer as ours is missing from the stores (Security Manager was informed last week). 2. We need to buy a new cable. The current one has been in place since 1982, and the insulation may have deteriorated. It should have been tested but sadly that has not been done. Phophi had been informed last year around August that it had been tested but alas that was not the case – we do not have the equipment to test it ourselves (we do not even have a mega on site). For that reason, we cannot use it as that will be in breach of the electrical installation regulations. 3. Again, not to fall foul of the electrical installation regulations we need to install an electrical isolator. That has not been procured. Please use your good offices to facilitate the procurement of these spares and hiring services. No 2025/05/07 15:00:00
RFQ/OBP033/2025/26 Request for Quote URGENT - Supply & install pipes and fittings on Production line We urgently need assistance with procuring certain critical spares needed for the freeze drier project. 1. We urgently need to cut the floor for the power supply cable. We will need to hire a jack hammer as ours is missing from the stores (Security Manager was informed last week). 2. We need to buy a new cable. The current one has been in place since 1982, and the insulation may have deteriorated. It should have been tested but sadly that has not been done. Phophi had been informed last year around August that it had been tested but alas that was not the case – we do not have the equipment to test it ourselves (we do not even have a mega on site). For that reason, we cannot use it as that will be in breach of the electrical installation regulations. 3. Again, not to fall foul of the electrical installation regulations we need to install an electrical isolator. That has not been procured. Please use your good offices to facilitate the procurement of these spares and hiring services. We urgently need assistance with procuring certain critical spares needed for the freeze drier project. 1. We urgently need to cut the floor for the power supply cable. We will need to hire a jack hammer as ours is missing from the stores (Security Manager was informed last week). 2. We need to buy a new cable. The current one has been in place since 1982, and the insulation may have deteriorated. It should have been tested but sadly that has not been done. Phophi had been informed last year around August that it had been tested but alas that was not the case – we do not have the equipment to test it ourselves (we do not even have a mega on site). For that reason, we cannot use it as that will be in breach of the electrical installation regulations. 3. Again, not to fall foul of the electrical installation regulations we need to install an electrical isolator. That has not been procured. Please use your good offices to facilitate the procurement of these spares and hiring services. No 2025/05/07 15:00:00
RFQ/OBP073/2025/26 Request for Quote Vacuum Oil For Freeze Dryer Supply vacuum pump oil for freeze dryer: Specifications: Vapor Pressure @ 25°C: 5 x 10^-5 Torr Viscosity @ 40°C: 26 cSt Flash Point: (COC) 180°C. 356°F Pour Point: -18°C. Specific Gravity @ 22°C: 0.86 g/m Supply vacuum pump oil for freeze dryer: Specifications: Vapor Pressure @ 25°C: 5 x 10^-5 Torr Viscosity @ 40°C: 26 cSt Flash Point: (COC) 180°C. 356°F Pour Point: -18°C. Specific Gravity @ 22°C: 0.86 g/m No 2025/07/03 15:00:00
RFQ/OBP049/2025/26 Request for Quote Validation of LFU's and air handling units for a period of 36months (SLA) ABOVE INCLUDES: 3 year VALIDATIONS - LAMINAR FLOW CABINETS - AIR HANDLING UNITS - BIOLOGICAL SAFETY CABINETS - FUME EXTRACTION CABINET LIST OF EQUIPMENT: 102- LF23 102-AHU06 102-AHU-07 102-LF12 102-LFU13 102-LFU-14 102-LFU15 102-LFU16 102-LF09 102-LF10 101-LF03 102-LF17 102-AHU01 102-AHU02 102-AHU03 102-AHU04 102-AHU05 102-LF03 102-LF02 102-LF04 102-LF05 102-LFU06 102-LFU20 102-LFU11 105-LF06 105-LF09 105-LF02 105-LF05 105-LF08 09913 105-LF03 105-LF10 10139 (HAND FILL) 103-LF03 103-LF09 RBV4090 FFV8024 101-LF01 101-LF02 101-LF04 100-LF01 100-LF04 100-LF05 108-LF14 108-LF09 108-LF11 108-AHU1 108-LF01 108-AHU02 108-LF05 108-LF03 108-LF12 106-LF05 106-LF06 106-LF04 106-LF02 106-LF01 106-LF03 102-LF21 106-LF07 107-LF-01 107-LF-02 107-AHU-01 107-AHU-02 107-AHU-03 107-AHU-04 ABOVE INCLUDES: 3 year VALIDATIONS - LAMINAR FLOW CABINETS - AIR HANDLING UNITS - BIOLOGICAL SAFETY CABINETS - FUME EXTRACTION CABINET LIST OF EQUIPMENT: 102- LF23 102-AHU06 102-AHU-07 102-LF12 102-LFU13 102-LFU-14 102-LFU15 102-LFU16 102-LF09 102-LF10 101-LF03 102-LF17 102-AHU01 102-AHU02 102-AHU03 102-AHU04 102-AHU05 102-LF03 102-LF02 102-LF04 102-LF05 102-LFU06 102-LFU20 102-LFU11 105-LF06 105-LF09 105-LF02 105-LF05 105-LF08 09913 105-LF03 105-LF10 10139 (HAND FILL) 103-LF03 103-LF09 RBV4090 FFV8024 101-LF01 101-LF02 101-LF04 100-LF01 100-LF04 100-LF05 108-LF14 108-LF09 108-LF11 108-AHU1 108-LF01 108-AHU02 108-LF05 108-LF03 108-LF12 106-LF05 106-LF06 106-LF04 106-LF02 106-LF01 106-LF03 102-LF21 106-LF07 107-LF-01 107-LF-02 107-AHU-01 107-AHU-02 107-AHU-03 107-AHU-04 2025/06/03 11:00:00 No 2025/06/09 15:00:00
RFQ/OBP366/2024/25 Request for Quote VAPROX Hydrogen Peroxide Sterilant 950ml Product Description Product Code Pack Size Qty VAPROX Hydrogen Peroxide Sterilant 950ml VHP-VAPPB006EUR 1 box (6 bottles) 6 Product Description Product Code Pack Size Qty VAPROX Hydrogen Peroxide Sterilant 950ml VHP-VAPPB006EUR 1 box (6 bottles) 6 No 2024/10/17 15:00:00
RFQ/OBP512/2024/25 Request for Quote Virkon powder To provide Virkon powder (10Litre) bucket X 10 To provide Virkon powder (10Litre) bucket X 10 No 2025/02/16 15:00:00
RFQ/OBP536/2024/25 Request for Quote WATER DISPENSER with 2 REFILLS This is part of the OHSA act, that the company must provide drinkable water to the employees that won't have an impact on their health. This is part of the OHSA act, that the company must provide drinkable water to the employees that won't have an impact on their health. No 2025/03/12 15:00:00
RFQ/OBP401/2024/25 Request for Quote Water Jacketed CO2 Incubator Equipment is on 2024/2025 Capex list and needs to be procured before financial year end. Equipment is on 2024/2025 Capex list and needs to be procured before financial year end. No 2024/11/13 15:00:00
RFQ/OBP513/2024/25 Request for Quote Wheelbarrows Provide 15X Wheelbarrows (Flat pan lasher) and 15X Galvanised baths (150 Litres) Provide 15X Wheelbarrows (Flat pan lasher) and 15X Galvanised baths (150 Litres) No 2025/02/16 15:00:00
RFQ/OBP4661/2024/25 Request for Quote White blank thermal labels See attached specifications See attached specifications No 2024/12/10 15:00:00
RFQ/OBP461/2024/25 Request for Quote White blank thermal labels See attached specifications See attached specifications No 2025/02/25 15:00:00
RFQ/OBP472/2024/25 Request for Quote White Carton strips PM0380 See attached specifications See attached specifications No 2025/01/30 15:00:00
RFQ/OBP472/2024/25 Request for Quote White Carton strips PM0380 See attached specifications See attached specifications No 2025/01/16 15:00:00
RFQ/OBP124/2025/26 Request for Quote Wire heating element Wire heating element Type:6220 Voltage:230vac Power: 2x500W min - 2 x 1300 W max Outer dimensions Length: 192mm Width: 35 mm Height: 41.5 mm Mounting length: 184.5mm For fans with roll length: 180mm Mark approval: UL/VDE Wire heating element Type:6220 Voltage:230vac Power: 2x500W min - 2 x 1300 W max Outer dimensions Length: 192mm Width: 35 mm Height: 41.5 mm Mounting length: 184.5mm For fans with roll length: 180mm Mark approval: UL/VDE No 2025/08/13 15:00:00